Internal Gear Pumps Link to homepage.

 

 

Internal Gear Pump Overview

Internal gear pump.Internal gear pumps are exceptionally versatile.  While they are often used on thin liquids such as solvents and fuel oil, they excel at efficiently pumping thick liquids such as asphalt, chocolate, and adhesives.  The useful viscosity range of an internal gear pump is from 1cPs to over 1,000,000cP.

In addition to their wide viscosity range, the pump has a wide temperature range as well, handling liquids up to 750°F / 400°C.  This is due to the single point of end clearance (the distance between the ends of the rotor gear teeth and the head of the pump).  This clearance is adjustable to accommodate high temperature, maximize efficiency for handling high viscosity liquids, and to accommodate for wear.

Rotor and idler.The internal gear pump is non-pulsing, self-priming, and can run dry for short periods.  They're also bi-rotational, meaning that the same pump can be used to load and unload vessels.  Because internal gear pumps have only two moving parts, they are reliable, simple to operate, and easy to maintain.

 

How Internal Gear Pumps Work

Fluid passing through the pump. 1. Liquid enters the suction port between the rotor (large exterior gear) and idler (small interior gear) teeth. The arrows indicate the direction of the pump and liquid.

2. Liquid travels through the pump between the teeth of the "gear-within-a-gear" principle. The crescent shape divides the liquid and acts as a seal between the suction and discharge ports.

3. The pump head is now nearly flooded, just prior to forcing the liquid out of the discharge port.  Intermeshing gears of the idler and rotor form locked pockets for the liquid which assures volume control.

4. Rotor and idler teeth mesh completely to form a seal equidistant from the discharge and suction ports. This seal forces the liquid out of the discharge port.

 

Advantages
  • Only two moving parts
  • Only one stuffing box
  • Non-pulsating discharge
  • Excellent for high-viscosity liquids
  • Constant and even discharge regardless of pressure conditions
  • Operates well in either direction
  • Can be made to operate with one direction of flow with either rotation
  • Low NPSH required
  • Single adjustable end clearance
  • Easy to maintain
  • Flexible design offers application customization
Disadvantages
  • Usually requires moderate speeds
  • Medium pressure limitations
  • One bearing runs in the product pumped
  • Overhung load on shaft bearing

 

Applications

Common internal gear pump applications include, but are not limited to:

 

Materials Of Construction / Configuration Options

 

Manufacturers

 


©2007, Pump School®
School Policy
Sponsored by Viking Pump, Inc.